1KV Heat Shrinkable Indoor and Outdoor Cable Termination Kits
HLVT
HLVT Type UA | HLVT Type CN | HLVT Type A |
Application
Indoor and outdoor terminations Type HLVT are designed to cover 3, 3.5 and 4-core plastic insulated cables (with PVC PE XLPE EPR outer sheath) with or without SWA/AWA/STA. The designs cover a wide range of cable cross section.
Features
Excellent electrical insulation
Environment sealing and weathering resistance
High mechanical protection
Wide cross section range suitable for all types of connectors
Compact design
Unlimited shelf life, allowing immediate reenergizing
Standard
EN 50393, DIN VDE 0278-393, BS 7933-2, IEC 60502-4
Kit contents
Adhesive lined core insulation tube
Low voltage breakout
Lug sealing tubes
Corrosion protection sleeve
Support ring and roll spring or armour clamp
Earth braid
Ordering Information
Heat Shrinkable Termination Kits for polymeric insulated cables with mechanical lugs.
Voltage | Part no. | Cross section mm2 | Cable Type (Unarmoured) | Connector Type |
---|---|---|---|---|
Uo/U(Um) 0.6/1.0(1.2)kV | HLVT-4/1.5-4/I-UA-M or HLVT-4/1.5-4/O-UA-M | 1.5-4 | UA | M |
HLVT-4/6-16/I-UA-M or HLVT-46-16/O-UA-M | 6-16 | UA | M | |
HLVT-4/25-50/I-UA-M or HLVT-4//25-50/O-UA-M | 25-50 | UA | M | |
HLVT-4/70-120/I-UA-M or HLVT-4/70-120/O-UA-M | 70-120 | UA | M | |
HLVT-4/150-240/I-UA-M or HLVT-4/150-240/O-UA-M | 150-240 | UA | M |
Heat Shrinkable Termination Kits for polymeric insulated cables with crimp lugs.
Voltage | Part no. | Cross section mm2 | Cable Type (Unarmoured) | Connector Type |
---|---|---|---|---|
Uo/U(Um) 0.6/1.0(1.2)kV | HLVT-4/1.5-4/I-UA-C or HLVT-4/1.5-4/O-UA-C | 1.5-4 | UA | C |
HLVT-4/6-16/I-UA-C or HLVT-4/6-16/O-UA-C | 6-16 | UA | C | |
HLVT-4/25-50/I-UA-C or HLVT-4/25-50/O-UA-C | 25-50 | UA | C | |
HLVT-4/70-120/I-UA-C or HLVT-4/70-120/O-UA-C | 70-120 | UA | C | |
HLVT-4/150-240/I-UA-C or HLVT-4/150-240/O-UA-C | 150-240 | UA | C |
Heat Shrinkable Termination Kits for polymeric insulated cables (concentric neutral) with mechanical lugs.
Voltage | Part no. | Cross section mm2 | Cable Type (concentric neutra) | Connector Type |
---|---|---|---|---|
Uo/U(Um) 0.6/1.0(1.2)kV | HLVT-4/10-25/I-CN-M or HLVT-4/10-25/O-CN-M | 10 -25 | CN | M |
HLVT-4/35-50/I-CN-M or HLVT-4/35-50/O-CN-M | 35 -50 | CN | M | |
HLVT-4/70-120/I-CN-M or HLVT-4/70-120/O-CN-M | 70 -120 | CN | M | |
HLVT-4/150-240/I-CN-M or HLVT-4/150-240/O-CN-M | 150 -240 | CN | M |
Heat Shrinkable Termination Kits for polymeric insulated cables (concentric neutral) with crimp lugs.
Voltage | Part no. | Cross section mm2 | Cable Type (concentric neutra) | Connector Type |
---|---|---|---|---|
Uo/U(Um) 0.6/1.0(1.2)kV | HLVT-4/10-16/I-CN-C or HLVT-4/10-16/O-CN-C | 10 -16 | CN | C |
HLVT-4/25-50/I-CN-C or HLVT-4/25-50/O-CN-C | 25 -50 | CN | C | |
HLVT-4/70-150/I-CN-C or HLVT-4/70-150/O-CN-C | 70 -150 | CN | C | |
HLVT-4/185-300/I-CN-C or HLVT-4/185-300/O-CN-C | 185 -300 | CN | C |
Heat Shrinkable Termination Kits for armoured polymeric insulated cables with mechanical/bolted lugs.
Voltage | Part no. | Cross section mm2 | Cable Type (armoured) | Connector Type |
---|---|---|---|---|
HLVT-4/1.5-10/I-A-M or HLVT-4/1.5-10/O-A-M | 1.5-10 | A | M | |
HLVT-4/10-25/I-A-M or HLVT-4/10-25/O-A-M | 10 -25 | A | M | |
HLVT-4/35-50/I-A-M or HLVT-4/35-50/O-A-M | 35 -50 | A | M | |
HLVT-4/70-120/I-A-M or HLVT-4/70-120/O-A-M | 70 -120 | A | M | |
HLVT-4/150-240/I-A-M or HLVT-4/150-240/O-A-M | 150 -240 | A | M |
Heat Shrinkable Termination Kits for armoured polymeric insulated cables with crimp lugs.
Voltage | Part no. | Cross section mm2 | Cable Type (armoured) | Connector Type |
---|---|---|---|---|
Uo/U(Um) 0.6/1.0(1.2)kV | HLVT-4/1.5-4/I-A-C or HLVT-4/1.5-4/O-A-C | 1.5-4 | A | C |
HLVT-4/6-16/I-A-C or HLVT-4/6-16/O-A-C | 6-16 | A | C | |
HLVT-4/25-50/I-A-C or HLVT-4/25-50/O-A-C | 25-50 | A | C | |
HLVT-4/70-150/I-A-C or HLVT-4/70-150/O-A-C | 70-150 | A | C | |
HLVT-4/185-300/I-A-C or HLVT-4/185-300/O-A-C | 185-300 | A | C |
Example: Kit part number : HLVT- 4/A/O-A -C
Where: HLVT- Heat Shrinkable Low Voltage Cable Terminations; 4-number of cable cores; A-cross section range of cable conductor; O-outdoor termination; A-the type of cable armour,SWA/AWA/STA; C- crimp type lugs.
No lugs supplied unless specified.
Technical Parameters
Performance of heat shrinkable low voltage cable terminations when tested according to EN 50393 (CENELEC 623 S1).
Test sequence | Item | Requirements acc. to Iec 60502.4 | Results | Performed test acc. to en 50393 |
---|---|---|---|---|
1 | Impulse Withstand Voltage Test | No breakdown shall occur at 10 positive and 10 negative impulses of 20kV | No breakdown shall occur at 10 positive and 10 negative impulses of 20kV | Pass |
2 | AC Withstand Voltage Test (In Air and Ambient Temperature) | 4kV,1min No breakdown | 4kV,1min No breakdown | Pass |
3 | Insulation Resistance (in Air and Ambient Temperature) | ≥ 50MΩ | ≥ 50MΩ | Pass |
4 | Impact Test (In Air and Ambient Temperature) | 4kg wedge dropped from a height of 1000mm | No functional Damage | Pass |
5 | AC Withstand Voltage Test Immersed in the water of with a Height of 1000mm | 4kV,1min No breakdown | 4kV,1min No breakdown | Pass |
6 | Heating Cycle Test in Air | Heat the conductor to 95℃- 100℃,63 times in air, No breakdown | Heat the conductor to 95℃- 100℃, 63 times in air, No breakdown | Pass |
7 | Heating Cycle Test (Immersed in the Water of with a Height of 1000mm) | Heat the conductor to 95℃- -100℃,63 times in the water, No breakdown | Heat the conductor to 95℃- -100℃,63 times in the water, No breakdown | Pass |
8 | AC Withstand Voltage Test (Immersed in the Water of with a Height of 1000mm) | 4kV,1min No breakdown | 4kV,1min No breakdown | Pass |
9 | Insulation Resistance (in Air and Ambient Temperature) | ≥ 50MΩ | ≥ 50MΩ | Pass |