CCL-CT 125PE |
|||
Product Name/Code : CCL-CT125PE |
Electrical Performance |
||
Application : |
Max. Conductor DC Resistance at 20 ¡æ ( ¦¸ /Km ) 8 9.00 |
15.2 |
|
For communication and signal control systems. |
Min. Insulation DC Resistance at 20 ¡æ ( M ¦¸ *Km ) |
>500 |
|
Reference Standard |
Operating Temperature( ¡æ ) |
70 |
|
Customer's sample spec. and the general standard |
Voltage Rating(V) |
1500 |
|
Cable Construction |
Capacitance(+/-3pF/m) |
55 |
|
Center Conductor |
Bare Copper |
Velocity ratio ( +/- 5 %) |
80 |
Diameter(mm) |
1 /1.25 |
Impedance(+/-3 ¦¸ ) |
75 |
Insulation |
Cellular PE |
Attenuation at 20 ¡æ (-dB/100m) |
|
Nom Thickness(mm) |
2.17 |
50MHz |
3.4 |
Insulation Diameter (¡À0.03mm) |
5.60 |
100MHz |
5.9 |
CU/Polyester tape | 100% |
200MHz |
7.0 |
Braid Shield |
Bare Copper Braid |
400MHz |
11.1 |
Construction |
16/4/0.14 |
700MHz |
13.0 |
Coverage Area(%) |
>=54 |
900MHz |
15.8 |
Sheathing |
PE |
1000MHz |
16.5 |
Min. Thickness(mm) |
1.05 |
|
|
Diameter(¡À0.10mm) |
7.80 |
|
|
Sheathing Compound |
PVC/LSF/LSOH |
|
|
Core Identification/Color Code |
According to customer request |
|
|
Bending Radius |
6xOverall Diameter |
|
|
Temperature Rating |
70 ¡æ |
|
|
Voltage Rating |
300/500V |
|
|
Fire Performance |
|
|
|
Flame Propagation Test to IEC 60332 Part 1 ( PVC /LSOH) |
|
|
|
Website: www.caledonian-cables.co.uk |
|
||
E-mail:sales@caledonian-cables.co.uk |
|