RG59MIL

Product Name/Code : RG59MIL

Electrical Performance

Application :

Electrical Characteristics:

For communication and signal control systems.

Frequency

Attenuation

Reference Standard

(MHz)

(dB/100m)

Customer's sample spec. and the general standard

50

4.3

100

8.0

Cable Construction

200

17.6

Center Conductor

Bare Copper/CCS

400

23.0

Dia.

1/0.584

700

28.4

Insulation

Solid PE

900

34.8

Nom. Thickness(mm)

1.56

1000

39.5

Insulation Dia. (±0.03mm)

3.7

Operating Temperature( ? )

60

Braid Shield

Bare Copper Braid

Capacitance(pF/m)

67

Construction

16/ 7/0.15

Velocity ratio (+/-5%)

66.7

Coverage Area(%)

>=93

 Impedance(+/-3 Ω )

  75

Jacket

PVC

Nom. Thickness(mm)

1.10

Cable Dia.(±0.10mm)

6.15

 

 

Jacket Compound

PVC/LSF/LSOH

 

 

Core Identification/Color Code

According to customer request

 

 

Bending Radius

6 x Overall Diameter

 

 

Temperature Rating

70C

 

 

Voltage Rating

300/500V

 

 

Fire Performance

 

 

 

Flame Propagation Test to IEC 60332 Part 1 ( PVC /LSOH)
Flame Propagation Test to IEC 60332 Part 1 and Part 3 ( FRPVC/LSFROH )
Determination of the amount Halogen Acid Gas to IEC 60754 Part 1 ( LSOH )
Smoke Density Test to IEC 61034 ( LSOH )
Oxygen Index Test to BS 2863 or ISO 4589-2 ( LSOH )
Temperature Index Test to BS 2782 or ISO 4589-3
( LSOH )

Website: www.caledonian-cables.co.uk

E-mail: sales@caledonian-cables.co.uk