RG62 LSF

Product Name/Code : RG62 LSF

Electrical Performance

Application :

Electrical Characteristics:

For communication and signal control systems.

Frequency

Attenuation

Reference Standard

(MHz)

(dB/100m)

Customer's sample spec. and the general standard

50

6.1

100

9.9

Cable Construction

200

12.7

Center Conductor

CCS

400

20.5

Dia.

1/0.643

700

26.9

Insulation

Tube PE

900

29.4

Nom. Thickness(mm)

1.5

1000

31.5

Insulation Dia. (±0.03mm)

4.6

Operating Temperature( ? )

60

Bare Copper Braid Shield

Capacitance(pF/m)

44.5

Construction

16/ 7/0.12

Velocity ratio (+/-5%)

66.7

Coverage Area(%)

>=86

 Impedance(+/-3 Ω )

93

Jacket

LSF

Nom. Thickness(mm)

0.78

Cable Dia.(±0.10mm)

6.15

 

 

Jacket Compound

PVC/LSF/LSOH

 

 

Core Identification/Color Code

According to customer request

 

 

Bending Radius

6 x Overall Diameter

 

 

Temperature Rating

70 ℃

 

 

Voltage Rating

300/500V

 

 

Fire Performance

 

 

 

Flame Propagation Test to IEC 60332 Part 1 ( PVC /LSOH)
Flame Propagation Test to IEC 60332 Part 1 and Part 3 ( FRPVC/LSFROH )
Determination of the amount Halogen Acid Gas to IEC 60754 Part 1 ( LSOH )
Smoke Density Test to IEC 61034 ( LSOH )
Oxygen Index Test to BS 2863 or ISO 4589-2 ( LSOH )
Temperature Index Test to BS 2782 or ISO 4589-3
( LSOH )

Website: www.caledonian-cables.co.uk

 

 