ALL DIELECTRIC SELF-SUPPORTING (ADSS) CABLE

Application:
The “All Dielectric Self-supporting (ADSS)” cable is designed for aerial self supporting application at short, medium and long span distances. ADSS cable offers a rapid and economical means for deployment by cable television operators, telephone companies and power utilities. It is adopted for high voltage, middle, small span conditions in Power Transmission System or mazy terrain such as river spanning, mountains.
Description: Construction:

The cable consists of 5 to 36 fiber containing tubes or fillers stranded in up to 3 layers around a central strength member and bound under a PE jacket. Each tube contains 6 -12 fibers. All the fibers in the cores are filled with water blocking gel. Fillers may be used to preserve the cable geometry. A water swelling tape is helically wrapped around the cable core. Aramid yarns are helically laid to supply peripheral strengthening of the cable. The outer jacket is tightly bound over the aramid yarn layer. The cable jacket incorporates an optional inner polyethylene jacket and an outer polyethylene or AT (anti-tracking) jacket. When the induction on cable surface is above 12KV, anti-tracking sheath material (AT) will be applied. With AT outer jacket, the maximum electric field strength at operating point can reach 35KV. For long span application, a double jacket design can be considered. An optional ripcord can be put under the jacket layer to faciliate its removal.

ADSS Cable

Physical Properties:

Span
(m)

Ice + Wind: 0mm + 35m/sec

Ice + Wind: 12mm + 30m/sec

Cable O.D.
(mm/in)

Cable Weight
(kg/km)/(lb/kft)

Max. Working Tension
(N/lb)

Max. Sag
(%)

Cable O.D.
(mm/in)

Cable Weight
(kg/km)/(lb/kft)

Max. Working Tension
(N/lb)

Max. Sag
(%)

100

13.9/5.472

152/102.01

7578/1704

2

13.8/0.543

150.0/100.67

6621/1489

2

200

14.3/0.562

161/108.05

10430/2346

3

14.1/0.555

157.0/105.37

9000/2024

3

400

15.9/0.625

199/133.56

23221/5223

3

15.4/0.606

187.0/125.50

19255/4331

3

500

16.7/0.657

220/147.65

30590/6881

3

16.1/0.633

204.0/136.91

24885/5598

3

600

16.3/0.641

209/140.27

26952/6063

4

15.7/0.618

196.0/131.54

22154/4983

4

800

16.5/0.649

216/144.97

29452/6625

5

15.9/0.625

201.0/134.90

24042/5408

6

1000

16.7/0.657

221/148.32

31271/7034

6

16.1/0.633

204.0/136.91

24407/5490

6

* Above table do not cover all of available types. Other ADSS cables can be manufactured upon customer's request according to different span and sag environment.

Mechanical Properties:

Minimum Bending Radius:
Under installation: 20×OD
During operation: 10×OD for unarmoured cables
20×OD for armoured cables
Temperature Range:
Operating Temperature Range: -40℃(-40℉) to +70℃(+158℉)
Storage Temperature Range: -50℃(-58℉) to +70℃(+158℉)

Maximum Compressive Load: 4000N
Repeated Impact: 4.4 N.m (J)
Twist (Torsion): 180×10 times, 125×OD
Cyclic Flexing: 100 cycles .
Crush Resistance: 220N/cm(125lb/in)

Fiber Compliance:

Temperature Cycling
Tensile Strength
Crush
Impact
Repeated Bending
Torsion
Kink
Cable Bend
Cool Bend

IEC60794-1-2-F2
IEC60794-1-2-E1A
IEC60794-1-2-E3
IEC60794-1-2-E4
IEC60794-1-2-E6
IEC60794-1-2-E7
IEC60794-1-2-E10
IEC60794-1-2-E11
IEC60794-1-2-E11

Safety Compliance:

General Purpose Grade
Flammability Test: OFN (UL1581)
Riser Grade
Flammability Test: OFNR/FT4 (UL1666)
Plenum Grade
Flammability Test: OFNP/FT6 (UL 910)
FRPVC Grade
Flammability Test: IEC60332-1
LSZH Grade

Halogen Content Test: IEC 60754-1
Acidity Test: IEC 60754;
Smoke Emission Test: IEC61034-1/2

LSFROH Grade

Halogen Content Test: IEC 60754-1
Acidity Test: IEC 60754;
Smoke Emission Test: IEC61034-1/2
Flammability Test: IEC60332-1 & IEC 60332-3C/A

FR Grade
Fire Resistance Test: IEC 60331 / BS 6387 CWZ

 

Standard Compliance:

Telcordia GR-20 RUS 7 CFR 1755.900 (REA PE-90) ICEA S 87-640 IEEE 1222

Features:

  • High capacity cable offer great flexibility for placement on overhead transmission towers, eliminating the need for a support messenger.
  • Dry core design and high tension strength capability suitable for toughest environmental and electrical conditions.
  • Fit for extra high voltage power lines without interruption of power service to the customers.
  • Typical spans with 1%-1.5% installation sag