Type G Four-Conductor Round Portable Power Cable 2kV

 

Applications :

  • These cables are designed for use with mobile mining equipment, such as continuous miners, cutting or loading machines, conveyors, drills or pumps.

Standards :

  • ICEA S-75-381/NEMA WC 58

     

    ASTM B 172

     

    ASTM B 33

     

    CAN/CSA C22.2 No. 96

Construction :

  • Conductor Stranded annealed tinned copper conductor.
    Insulation Ethylene Propylene Rubber (EPR).
    Grounding Conductor Tinned copper conductor with an optional green outer covering.
    Jacket Reinforced heavy-duty/extra-heavy-duty Chlorinated Polyethylene (CPE), black. (Cables having a nominal outside diameter of more than 2.0 inches require extra-heavy-duty jackets.)

Options :

  • Other jacket materials such as CSP/PCP/NBR/PVC are available upon request.
  • Two-layer jacket with reinforcing fibre between the two layers can be offered as an option.

Mechanical and Thermal Properties :

  • Minimum Bending Radius: 6×OD.
  • Maximum Conductor Operating Temperature: +90℃.

Dimensions and Weight :

  • Construction No. of
    Strands
    Grounding
    Conductor
    Size
    Nominal Insulation
    Thickness
    Nominal Jacket
    Thickness
    Nominal Overall
    Diameter
    Nominal Weight Ampacity
    No. of cores
    ×AWG/kcmil
    - AWG/
    kcmil
    inch mm inch mm inch mm lbs/kft kg/km A
    4×6 259 12 0.06 1.5 0.140 3.6 1.10 27.9 910 1354 72
    4×4 412 10 0.06 1.5 0.155 3.9 1.27 32.3 1378 2050 93
    4×2 259 9 0.06 1.5 0.170 4.3 1.48 37.6 1914 2848 122
    4×1 331 8 0.08 2.0 0.190 4.8 1.68 42.7 2311 3438 143
    4×1/0 414 7 0.08 2.0 0.190 4.8 1.79 45.5 2810 4181 165
    4×2/0 522 6 0.08 2.0 0.190 4.8 1.93 49.0 3253 4840 192
    4×3/0 658 5 0.08 2.0 0.205 5.2 2.07 52.6 4099 6099 221
    4×4/0 829 4 0.08 2.0 0.220 5.6 2.26 57.4 4925 7327 255
    4×250 973 3 0.095 2.4 0.235 6.0 2.66 67.6 6060 9016 280
    4×350 1361 1 0.095 2.4 0.250 6.4 2.98 75.7 8126 12090 335
    4×500 1921 1/0 0.095 2.4 0.280 7.1 3.40 86.4 10758 16006 395
  • Ampacity-Based on a conductor temperature of 90℃ and an ambient air temperature of 40℃, per ICEA S-75-381.