M81381/14

Application and Description:

These FEP/polyimide/FEP tape insulated single-core M81381/14 cables are used in aerospace applications and other challenging applications. It is well-suited to applications concerned with smoke emission and overload stability.

Construction:

Conductor: Stranded nickel-plated high-strength copper alloy conductor

Insulation: FEP/polyimide/FEP tape insulation

Insulation Wall Thickness: 0.0065”

Jacket: modified aromatic poyimide coating 

Characteristics:

Temperature Range: -55°C + 200°C

Voltage Rating: 600 volts

Color Code: MIL-STD-104 (See page 42 )

10 basic colors(BLK,BRN,RED,ORN,YEL,GRN,BLU,VIO,GRY,WHT)

Dimensions and Weight:

AWG Size

Conductor Stranding

Conductor Diam.

Max.

Conductor Diam.

Min.

Max. O.D.

Min. O.D.

Maximum Resistance (Ohm/1000' @ 20°C)

Approx LBS/MFT

 

 

in

mm

in

mm

in

mm

in

mm

   

28

7/36

0.016

0.410

0.014

0.360

0.035

0.889

0.031

0.787

79.00

1.2

26

19/38

0.020

0.510

0.018

0.460

0.040

1.016

0.036

0.914

49.40

1.3

24

19/36

0.025

0.640

0.023

0.580

0.045

1.143

0.041

1.041

30.10

1.9

22

19/34

0.031

0.790

0.029

0.740

0.051

1.295

0.047

1.194

18.60

2.8

20

19/32

0.040

1.020

0.037

0.940

0.060

1.524

0.059

1.499

11.40

4.2

 

 