RF 400 LRP

 

Construction :

  • Inner conductor Plain copper 2.62 mm
    Dielectric Gas injected foam PE Φ7.20 ± 0.10 mm
    Outer conductor (shield 1) Copper + polyester tape
    Shield coverage   100%
    Outer conductor (shield 2) Plain copper 96 x 0.15 mm
    Shield coverage   56%
    Sheath PVC or LSZH Φ10.30 ± 0.18 mm
  •  

Electrical & Mechanical Characteristics :

  • Impedance 50±3 Ohm
    Nominal capacitance 80 pF/m
    Velocity of propagation 84%
    Insulation resistance >5000 Mohm.Km
    Inner conductor resistance 3.2 Ohm/Km
    Outer conductor resistance 12.7 Ohm/Km
    Operating temperature range -30 °C - +70 °C
    Copper weight 71.3Kg/Km
    Cable weight (approx.) 137.7 Kg/Km
    Screening effectiveness >80 dB

Attenuation :

  • Frequency(MHz) Attenuation (dB/100 m) Attenuation (dB/100ft)
    50 2.5 0.76
    100 3.6 1.10
    400 7.9 2.41
    600 10.1 3.08
    860 12.1 3.69
    1000 13.2 4.02
    1750 18.7 5.70
    2400 22.2 6.77

Return Loss :

  • 30-300 MHz >29dB
    300-600 MHz >26dB
    600-900 MHz >24dB
>