FMGCH-FFR 150/250V Mica Tape + XLPE Insulated, LSOH (SHF1) Sheathed, Armoured Fire Resistant Instrumentation & Control Cables (Multipair/Multitriple)

Applications

These cables are used on board of ships in all locations for fixed installations complying with IEC standards 60092-352 in safety circuit, where fire resistance is required. These cables are fire resistant, flame retardant, low smoke & halogen free, suitable for installations on passenger ships, as on other commercial vessels.

Standards

  • IEC 60092-350/351/376/359
  • IEC 60331-21
  • IEC 60332-1
  • IEC 60332-3-22
  • IEC 60754-1/2
  • IEC 61034

Construction

FMGCH-FFR
Conductors Class 2 stranded copper conductor.
Insulation Mica tape + XLPE.
Cabling Element Pair/Triple.
Inner Covering Lapped polyester tape.
Armour Copper wire braid.
Outer Sheath LSOH (SHF1).

Core Identification

Pair White/blue with printed pair number and core number.
Triple White/blue/red with printed triple number.

Mechanical and Thermal Properties

Bending Radius for Fixed Installations 6×OD
Temperature Range -30℃ ~ +80℃

Dimensions and Weight

Part No. Construction No. of elements×No. of cores in element×Cross section Nominal Insulation Thickness Nominal Sheath Thickness Nominal Overall Diameter Nominal Weight
  mm^2 mm mm mm kg/km
FMGCH-FFR -1P0.75 1×2×0.75 0.5 1.3 9.1 120
FMGCH-FFR -2P0.75 2×2×0.75 0.5 1.3 10.2 150
FMGCH-FFR -3P0.75 3×2×0.75 0.5 1.8 14.6 280
FMGCH-FFR -4P0.75 4×2×0.75 0.5 1.8 15.4 320
FMGCH-FFR -5P0.75 5×2×0.75 0.5 1.9 17.2 390
FMGCH-FFR -6P0.75 6×2×0.75 0.5 1.9 18.3 440
FMGCH-FFR -7P0.75 7×2×0.75 0.5 1.9 18.3 460
FMGCH-FFR -8P0.75 8×2×0.75 0.5 2.0 19.6 520
FMGCH-FFR -10P0.75 10×2×0.75 0.5 2.0 21.7 620
FMGCH-FFR -12P0.75 12×2×0.75 0.5 2.1 22.8 700
FMGCH-FFR -14P0.75 14×2×0.75 0.5 2.1 23.6 770
FMGCH-FFR -16P0.75 16×2×0.75 0.5 2.2 25.4 870
FMGCH-FFR -19P0.75 19×2×0.75 0.5 2.2 27.0 990
FMGCH-FFR -20P0.75 20×2×0.75 0.5 2.2 27.0 1010
FMGCH-FFR -24P0.75 24×2×0.75 0.5 2.4 30.9 1240
FMGCH-FFR -30P0.75 30×2×0.75 0.5 2.5 33.5 1480
FMGCH-FFR -37P0.75 37×2×0.75 0.5 2.6 35.9 1730
FMGCH-FFR -1P1.0 1×2×1.0 0.5 1.3 9.5 130
FMGCH-FFR -2P1.0 2×2×1.0 0.5 1.3 10.7 170
FMGCH-FFR -3P1.0 3×2×1.0 0.5 1.8 15.3 320
FMGCH-FFR -4P1.0 4×2×1.0 0.5 1.8 16.2 360
FMGCH-FFR -5P1.0 5×2×1.0 0.5 1.9 18.1 440
FMGCH-FFR -6P1.0 6×2×1.0 0.5 2.0 19.5 510
FMGCH-FFR -7P1.0 7×2×1.0 0.5 2.0 19.5 530
FMGCH-FFR -8P1.0 8×2×1.0 0.5 2.0 20.7 590
FMGCH-FFR -10P1.0 10×2×1.0 0.5 2.1 23.2 730
FMGCH-FFR -12P1.0 12×2×1.0 0.5 2.1 24.1 810
FMGCH-FFR -14P1.0 14×2×1.0 0.5 2.2 25.1 900
FMGCH-FFR -16P1.0 16×2×1.0 0.5 2.2 26.9 1010
FMGCH-FFR -19P1.0 19×2×1.0 0.5 2.3 28.8 1160
FMGCH-FFR -20P1.0 20×2×1.0 0.5 2.3 28.8 1190
FMGCH-FFR -24P1.0 24×2×1.0 0.5 2.5 33.0 1460
FMGCH-FFR -30P1.0 30×2×1.0 0.5 2.6 35.8 1740
FMGCH-FFR -37P1.0 37×2×1.0 0.5 2.9 38.8 2140
FMGCH-FFR -1P1.5 1×2×1.5 0.6 1.3 10.5 160
FMGCH-FFR -2P1.5 2×2×1.5 0.6 1.4 12.1 220
FMGCH-FFR -3P1.5 3×2×1.5 0.6 1.9 17.4 400
FMGCH-FFR -4P1.5 4×2×1.5 0.6 1.9 18.4 470
FMGCH-FFR -5P1.5 5×2×1.5 0.6 2.0 20.6 570
FMGCH-FFR -6P1.5 6×2×1.5 0.6 2.1 22.2 660
FMGCH-FFR -7P1.5 7×2×1.5 0.6 2.1 22.2 700
FMGCH-FFR -8P1.5 8×2×1.5 0.6 2.1 23.6 780
FMGCH-FFR -10P1.5 10×2×1.5 0.6 2.2 26.5 950
FMGCH-FFR -12P1.5 12×2×1.5 0.6 2.3 27.7 1070
FMGCH-FFR -14P1.5 14×2×1.5 0.6 2.3 28.7 1180
FMGCH-FFR -16P1.5 16×2×1.5 0.6 2.4 31.0 1350
FMGCH-FFR -19P1.5 19×2×1.5 0.6 2.5 33.2 1560
FMGCH-FFR -20P1.5 20×2×1.5 0.6 2.5 33.2 1590
FMGCH-FFR -24P1.5 24×2×1.5 0.6 2.9 38.5 2060
FMGCH-FFR -30P1.5 30×2×1.5 0.6 3.0 41.8 2450
FMGCH-FFR -37P1.5 37×2×1.5 0.6 3.1 44.7 2880
FMGCH-FFR -1T0.75 1×3×0.75 0.5 1.3 9.5 130
FMGCH-FFR -2T0.75 2×3×0.75 0.5 1.8 14.9 290
FMGCH-FFR -3T0.75 3×3×0.75 0.5 1.8 15.7 340
FMGCH-FFR -4T0.75 4×3×0.75 0.5 1.9 17.2 410
FMGCH-FFR -5T0.75 5×3×0.75 0.5 1.9 18.8 480
FMGCH-FFR -6T0.75 6×3×0.75 0.5 2.0 21.2 590
FMGCH-FFR -7T0.75 7×3×0.75 0.5 2.0 21.2 620
FMGCH-FFR -8T0.75 8×3×0.75 0.5 2.1 22.8 700
FMGCH-FFR -10T0.75 10×3×0.75 0.5 2.2 25.7 860
FMGCH-FFR -12T0.75 12×3×0.75 0.5 2.2 27.0 970
FMGCH-FFR -14T0.75 14×3×0.75 0.5 2.3 28.3 1080
FMGCH-FFR -16T0.75 16×3×0.75 0.5 2.3 29.9 1200
FMGCH-FFR -19T0.75 19×3×0.75 0.5 2.4 32.3 1390
FMGCH-FFR -20T0.75 20×3×0.75 0.5 2.5 33.0 1460
FMGCH-FFR -24T0.75 24×3×0.75 0.5 2.6 35.9 1710
FMGCH-FFR -30T0.75 30×3×0.75 0.5 2.9 40.1 2170
FMGCH-FFR -32T0.75 32×3×0.75 0.5 3.0 41.7 2320
FMGCH-FFR -1T1.0 1×3×1.0 0.5 1.3 9.9 150
FMGCH-FFR -2T1.0 2×3×1.0 0.5 1.8 15.6 320
FMGCH-FFR -3T1.0 3×3×1.0 0.5 1.8 16.5 380
FMGCH-FFR -4T1.0 4×3×1.0 0.5 1.9 18.1 470
FMGCH-FFR -5T1.0 5×3×1.0 0.5 2.0 20.1 560
FMGCH-FFR -6T1.0 6×3×1.0 0.5 2.1 22.6 680
FMGCH-FFR -7T1.0 7×3×1.0 0.5 2.1 22.6 720
FMGCH-FFR -8T1.0 8×3×1.0 0.5 2.1 24.1 810
FMGCH-FFR -10T1.0 10×3×1.0 0.5 2.2 27.2 990
FMGCH-FFR -12T1.0 12×3×1.0 0.5 2.3 28.8 1130
FMGCH-FFR -14T1.0 14×3×1.0 0.5 2.3 30.0 1260
FMGCH-FFR -16T1.0 16×3×1.0 0.5 2.4 31.9 1410
FMGCH-FFR -19T1.0 19×3×1.0 0.5 2.5 34.4 1640
FMGCH-FFR -20T1.0 20×3×1.0 0.5 2.5 35.0 1700
FMGCH-FFR -24T1.0 24×3×1.0 0.5 2.9 38.8 2110
FMGCH-FFR -30T1.0 30×3×1.0 0.5 3.0 42.8 2560
FMGCH-FFR -32T1.0 32×3×1.0 0.5 3.1 44.4 2730
FMGCH-FFR -1T1.5 1×3×1.5 0.6 1.3 11.0 180
FMGCH-FFR -2T1.5 2×3×1.5 0.6 1.9 17.7 410
FMGCH-FFR -3T1.5 3×3×1.5 0.6 1.9 18.7 490
FMGCH-FFR -4T1.5 4×3×1.5 0.6 2.0 20.6 610
FMGCH-FFR -5T1.5 5×3×1.5 0.6 2.1 22.9 740
FMGCH-FFR -6T1.5 6×3×1.5 0.6 2.2 25.8 890
FMGCH-FFR -7T1.5 7×3×1.5 0.6 2.2 25.8 950
FMGCH-FFR -8T1.5 8×3×1.5 0.6 2.3 27.7 1070
FMGCH-FFR -10T1.5 10×3×1.5 0.6 2.4 31.3 1320
FMGCH-FFR -12T1.5 12×3×1.5 0.6 2.5 33.2 1520
FMGCH-FFR -14T1.5 14×3×1.5 0.6 2.5 34.6 1690
FMGCH-FFR -16T1.5 16×3×1.5 0.6 2.8 37.3 1990
FMGCH-FFR -19T1.5 19×3×1.5 0.6 2.9 40.3 2310
FMGCH-FFR -20T1.5 20×3×1.5 0.6 3.0 41.1 2420
FMGCH-FFR -24T1.5 24×3×1.5 0.6 3.1 44.7 2840
FMGCH-FFR -30T1.5 30×3×1.5 0.6 3.3 49.5 3460
FMGCH-FFR -32T1.5 32×3×1.5 0.6 3.3 51.2 3670

*: 2 pairs are assembled as a quad.