FIREROL Thin Wall Multipair Overall Screen Cables with Standrad Wall Sheath 300/500V
EN 50306-4 (FRL-TW-05MP-SW-OS)
Application
-Used as signal and control cable for protected installations inside and outside of rail and transport vehicles, where space and weight are an important factor.
-Used in cable harnesses, switchboards and control panels, driver desks etc.
Construction
Conductor |
Tinned annealed copper wires as defined in EN 50306-2 |
Insulation |
LSZH special compound |
Pair Identification |
Pairs numbered according to EN 50306-4 |
Overal Screen |
Tinned annealed copper wires |
Outer Sheath |
LSZH special compound (S2, EM 101 - EM 104) |
Electrical & Mechanical Properties
Nominal Voltage |
300/500 V |
Max. Conductor Temperature |
90°C /105°C (fixed installation) |
Min. Permissible Ambient Temperature |
-25°C/-40°C (fixed installation) |
Bending Radius |
10 x Overall Diameter |
Chemical & Environmental Propertie
EN 60684-2 |
No fluorine |
EN 50305; EN 60811-2-1 |
Resistance to mineral oil & fuel oil, acid & alkali |
EN 50305 |
Resistance to ozone |
Fire Performance for rolling stock application
EN 50306-2 |
Hazard levels HL1, HL2, HL3 |
DIN 5510-2 |
Protection level 1/2/3/4 |
BS 6853 |
Interior use 1a, 1b, II; Exterior use 1a, 1b, II |
NF F 16-101 |
F0 |
EN54454-2 |
R15 Interior/ R16 Exterior HL1, HL2, HL3 |
Fire Performance in General
EN 50265-2-1; IEC 60332-1-2; NF C 32-070 2.1 (C2) |
Vertical flame propogation for a single insulated wire or cable |
EN 50266-2-4 + EN 50305; IEC 60332-3-24; NF C 32-070 2.2 (C1); VDE 0472 Teil 804 |
Vertical flame spread of vertically mounted bunched wires or cables |
EN 50268-2; IEC 61034-2; NF C 32-073 ; NF C 20-902; NF F 16 101; VDE 0472 Teil 816 |
Low Smoke Emission |
EN 50267-2-1; IEC 60754-1; NF C 32-074; NF C 20-454; VDE 0472 Teil 815 |
Halogen Free |
EN 50267-2-2/3; IEC 60754-2; NF C 32-074; NF C 20-453; VDE 0472 Teil 813 |
Low Corrosivity (Acidity & Conductivity) |
EN 50305; NF X 70-100; NF F 63 808; TM1-04; BS6853 |
Low Toxicity |
NF F 63 808; BS6853; NF F 16 101 |
Smoke index |
EN45545-2 |
Requirement for fire behavior of materials & components R15/R16 |
FRL-TW-05MP-ESW-OS 300/500 V
Number of Cores x Nominal Cross Section |
Min. Thickness of Sheath at any Point |
Overall Diameter |
Weight |
Min. |
Max. |
n x mm² |
mm |
mm |
mm |
kg/km |
2 x 2 x 0.5 |
0.56 |
6.6 |
7.9 |
61 |
3 x 2 x 0.5 |
0.56 |
7.0 |
8.1 |
78 |
4 x 2 x 0.5 |
0.56 |
7.7 |
8.7 |
96 |
7 x 2 x 0.5 |
0.56 |
9.0 |
10.6 |
146 |
|
2 x 2 x 0.75 |
0.56 |
7.1 |
9.0 |
80 |
3 x 2 x 0.75 |
0.56 |
7.7 |
9.2 |
103 |
4 x 2 x 0.75 |
0.56 |
9.0 |
10.0 |
128 |
7 x 2 x 0.75 |
0.56 |
10.8 |
11.8 |
200 |
|
2 x 2 x 1.0 |
0.56 |
7.8 |
9.5 |
95 |
3 x 2 x 1.0 |
0.56 |
8.3 |
9.7 |
125 |
4 x 2 x 1.0 |
0.56 |
9.1 |
10.3 |
156 |
7 x 2 x 1.0 |
0.56 |
11.0 |
12.4 |
247 |
|
2 x 2 x 1.5 |
0.56 |
9.8 |
11.2 |
126 |
3 x 2 x 1.5 |
0.56 |
10.4 |
11.4 |
168 |
4 x 2 x 1.5 |
0.56 |
11.6 |
12.6 |
212 |
7 x 2 x 1.5 |
0.56 |
14.0 |
15.3 |
340 |